Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. dent. sci ; 23(3): 1-12, 2020. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1116334

ABSTRACT

Objetivo: Este estudo teve como objetivo avaliar a resistência ao desgaste de dentes em acrílico para próteses contendo nanopartículas de dióxido de silício (nano-SiO2 ) e dióxido de alumínio (nanoAl2 O3 ). Material e Métodos: O material em polimetilmetacrilato (PMMA) foi utilizado para fabricar 84 amostras (n=10) contendo nano-SiO2 e nano-Al2 O3 nas concentrações 0,1% em peso, 0,3% em peso e 0,5% em peso de pó acrílico. Uma máquina de teste de desgaste de dois corpos e um microscópio digital foram usados para medir as mudanças na perda de peso e rugosidade da superfície, respectivamente. Testes de ANOVA a um fator e testes de comparações múltiplas de Tukey foram utilizados para análise dos dados (α = 0,05). Resultados: O material modificado com nano-SiO2 demonstrou um aumento significativo na perda de peso em comparação com o material acrílico artificial convencional (p ˂ 0,05) enquanto o material modificado com nano-Al2 O3 demonstrou aumento não significativo na perda de peso, exceto no subgrupo 0,5% (p < 0,05). Não há diferenças significativas em relação à alteração da rugosidade após a simulação de desgaste entre todos os grupos testados (p > 0,05). Conclusão: As nanopartículas de nano-Al2 O3 exibem menos efeito negativo que o nanoSiO2 , podendo ser usado com cautela, se necessário. (AU)


Objective: This study aimed to evaluate the wear resistance of acrylic denture teeth containing silicon dioxide (nano-SiO2 ) and aluminum dioxide (nano-Al2 O3 ) nanoparticles. Material and Methods: Poly methyl methacrylate (PMMA) denture tooth material was used to denture tooth material was used to fabricate 84 specimens (n=10) containing nano-SiO2 and nano-Al2 O3 in concentrations 0.1wt%, 0.3wt%, and 0.5wt% of acrylic powder. A two-body wear testing machine and digital microscope were used to measure the changes in weight loss and surface roughness respectively. One-way ANOVA and pair-wise Tukey's post-hoc tests were used for data analysis (α = 0.05). Results: Nano-SiO2 modified teeth material demonstrated a significant increase in weight loss in comparison conventional artificial acrylic teeth material (p ˂ 0.05) while nanoAl2 O3 modified teeth material demonstrated non-significant increase in weight loss except for 0.5% subgroup (p ˂ 0.05). There is no significant differences regarding roughness change after wear simulation among all tested groups (p > 0.05). Conclusion: Nano-Al2 O3 nanoparticles exhibit less negative effect than nano-SiO2 so; it could be used with caution if necessary. (AU)


Subject(s)
Dental Prosthesis , Polymethyl Methacrylate , Metal Nanoparticles , Tooth Wear
2.
Braz. dent. sci ; 23(3): 1-6, 2020. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1104370

ABSTRACT

Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether ether ketone (PEEK). Material and Methods: sixteen models were fabricated,each one having lower 1st molar. Models were divided into two groups according to materials,group I (GI) for cobalt chromium (Co-Cr) and group II (GII) for PEEK. Each testing models and its clasps were mounted inside universal testing machine, the retention was measured by applying withdrawal force to it by this machine at 5 mm/min. The Fatigue resistance is measured by the reduction in retention through repeated insertion and removal cycles using robota chewing simulator. Removal and insertion cycling of clasps was carried out for 360, 730, 1080, 1,440, 2,116 and 2,880 cycles (corresponding to 3, 6, 9, 12, 18 and 24 months of simulated clinical use of a RPD) to simulate the fatigue resistance test. Deformity was measured before and after each cycling using a digital micrometer. Statistical analysis was done by 2-way-ANOVA test to detect significance effects of each variable. Results: Retention and fatigue resistance, after 360, 730, 1080, 1,440, 2,116 and 2,880 cycles totally the difference between Co-Cr and PEEK groups was statistically non-significant (P = 0.0980> 0.05) where (Co-Cr > PEEK). Deformation results, regardless to evaluation time, Co-Cr group recorded statistically significant higher deformation mean value than PEEK group (P = 0.008 < 0.05).Regardless to material group, deformation mean value changed nonsignificantly by time (P = 0.2882> 0.05). Conclusion: PEEK clasps (1.0 mm in cross section diameter) engage 0.50 mm undercut provide sufficient retention nearly similar that of Co-Cr clasps.(AU)


Objetivo: o objetivo foi avaliar a força de retenção, a resistência à fadiga e a deformidade dos grampos fabricados com dois materiais diferentes: cromo-cobalto (Co-Cr) e poliéter-éter-étercetona (PEEK). Materiais e métodos: dezesseis modelos foram confeccionados, cada um com 1º molar inferior. Os modelos foram divididos em dois grupos de acordo com o material: grupo I Co-Cr e grupo II para PEEK. Cada modelo de teste universal e seus grampos foram montados em uma máquina de teste universal. A retenção foi medida aplicando força de retirada por esta máquina a 5 mm/min. A resistência à fadiga foi medida pela redução na retenção através de ciclos repetidos de inserção e remoção usando um simulador do ciclo de mastigação. O ciclo de remoção e inserção dos grampos foi realizado por 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos (correspondendo a 3, 6, 9, 12, 18 e 24 meses de uso clínico simulado de um RPD) para simular o teste de resistência à fadiga. A deformidade foi medida antes e após cada ciclo, usando um micrômetro digital. A análise estatística foi realizada pelo teste ANOVA de 2 fatores para detectar os efeitos de significância de cada variável. Resultados: A retenção e a resistência à fadiga após 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos entre os grupos Co-Cr e PEEK não mostrou diferença estatisticamente significativa (p = 0,0980> 0,05), onde (Co-Cr> PEEK). Para os resultados da deformação, independentemente do tempo de avaliação, o grupo Co-Cr registrou um valor médio de deformação maior, com diferença estatística significativa, quando comparado com o grupo PEEK (p= 0,008 < 0,05). Independentemente do grupo de material, o valor médio da deformação foi alterado de forma não significativa pelo tempo (p= 0,2882> 0,05). Conclusão: os grampos PEEK (1,0 mm de diâmetro da seção transversal) engatam 0,50 mm retenção quase semelhante à dos grampos Co-Cr (AU)


Subject(s)
Resins, Synthetic , Chromium Alloys , Denture, Partial
SELECTION OF CITATIONS
SEARCH DETAIL